INDUSTRIAL HEATING: HOW TO HEAT LARGE BUILDINGS

HOT AIR GENERATORS FOR INDUSTRY

Heat large buildings effectively and professionally during the winter

Heating large buildings, such as warehouses, workshops and industrial buildings, which have large spaces, during the colder months is a fundamental imperative to allow constant and continuous work. But is it possible to obtain a high thermal capacity by limiting heating costs?

Industrial heating is a necessity linked to the well-being of the operators

The difficulty that arises, when the external degrees begin to fall, is to maintain a stable temperature despite the large volumes and the frequent exchange of warm and lukewarm air due to the opening of the doors, which cause a rapid internal cooling. It is therefore necessary that these spaces are quickly heated, so that the internal drop is immediately resolved with new and rapid heat. The hot air generators for the industry must therefore guarantee the maintenance of comfortable temperatures for the workers and, at the same time, avoid waste of energy (and therefore of money) to go and completely heat the air zones and volumes unnecessarily not significant.

Traditional heating systems are not suitable for industrial heating

This is because they direct the heat and, consequently, the hot air will disperse and accumulate in the upper areas of the room without giving comfort to the actual work spaces, also moving dust and dust inside the room that generate "pollution".

They require the installation of the thermal power plant and of the various pipes required, with bureaucratic procedures Furthermore, the time required to heat an entire shed is very long with very high fuel consumption and costs that are exaggerated.

The solution? BIEMMEDUE hot air generators

The BM2 hot air generators designed for the industry combine innovative design, quality of the materials used and product safety.

They are very silent machines (suitable for enclosed spaces) with a vertical structure and all with indirect combustion: they use a high-performance heat exchanger that allows the evacuation of fumes through a chimney that can be connected to the outside.

BIEMMEDUE generators for the industry

VERTIGO - PLUG AND PLAY CABINET SPACE HEATERS

  • Low-noise forced air space heaters suitable for indoor facilities

  • Integrated burner oil

  • Electronic flame-control

  • Room thermostat integrated (+5°/+30° C) and can be connected to remote ambient thermostat

  • Reverse blades radial fan

  • Power cord (1,5 m) with plug

  • Oil filter

  • Stainless steel combustion chamber with aerodynamic shape

  • High efficiency heat exchanger

  • 35 liters fuel tank with level gauge

  • Stainless steel exhaust passplate pipe l = 0,6 m

  • Pre-heating and automatic post ventilation of the combustion chamber

  • Summer-winter switch for use as a fan

  • Air recycling option when heater is placed outside the facilities (bar, restaurant, etc.)

  • Air inlet/outlet grills

  • Can be moved on retractable wheels

  • Easy maintenance


CONFORT - PLUG&PLAY CABINET HEATERS

  • Erp 2018 compliant

  • Automatic oil burner

  • Electronic flame control

  • Built-in electronic room thermostat (0°/+40° C)

  • Centrifugal fan

  • Automatic reset FAN-LIMIT bi-thermostat

  • Manual reset safety overheat thermostat

  • Power cord with plug

  • 16 hours runtime integrated fuel tank

  • Integrated fuel level indicator

  • Double skinned body for thermo-acoustic insulation and safe low surface temperature

  • High efficiency stainless steel combustion chamber with aerodynamic shape

  • Pre-heating and automatic post ventilation of the combustion chamber


SP - INDUSTRIAL CABINET HEATERS

  • Burner is supplied with snorkel outlet to ensure clean combustion air through connection with external air aspiration duct

  • The new heat exchanger combined with the new high-performance fans allow for heat output of 92 / 93%

  • Before heating and after cooling of combustion chamber

  • Panel with reinforcement cross pleats to ensure superior rigidity and strenght (SP 110-235)

  • Thermostat: FAN for fan control; LIMIT: for burner control; OVERHEATING: safety thermostat in case of overheating, with manual reset

  • Bearing structure with removable panels for internal washing, even on hanging machines

  • All installation inserts and screws are exclusively metric, not self-tapping

  • Ventilator (IP 55):

    - very low noise fan (noise level ≤ 69db at 2 meters)

    - high output, high performance fan guarantees increased air flow and static pressure (500 Pa) for uniform and long distance diffusion of warm air through channels or ducts

    - fan anchorage on machine’s bearing structure through sturdy rods

    - adjustable fresh air re-uptake shutter (SP 110-235)

  • Control rear electrical panel (IP 65):

    - can be connected to thermostat/humidistat/timer

    - Integrated in the bottom side

Before deciding definitively which hot air generator to choose the heating of your own industry, warehouse, warehouse and / or workshop, it is important to understand which surfaces you want to heat, the required temperature, the efficiency and the capacity of the heater